Thermal Management Applied to Data Centers with Focus on Energy Efficiency

Roger Schmidt, IBM Fellow, IBM Chief Engineer - Data Center Energy Efficiency

Faculty Host: Ricardo Bianchini

Abstract

Recent surveys of CIO’s have shown that energy is one of the leading concerns in the operation of data centers.   The IT industry ranks 6th in overall energy use compared to other large industries and if the manufacturing of IT equipment which ranks 11th is included with the power required to drive all the IT equipment then this industry is 3rd on the list of industries which use the most energy in the US.  (See the NYTimes front page article, Sunday, Sept 23, 2012 entitled “Power, Pollution and the Internet"). The EPA issued a report to the US Congress in August, 2007 and as requested through the House of Representatives to prepare a study to assess opportunities for energy efficiency improvements to computer servers and data centers in the United States.  Two points stand out in this report:1)the infrastructure support of the IT equipment within a data center contributes over 1/2 of the overall power used for maintaining a data center, and 2)the rate of growth of data center energy usage is significant.  Since that report IBM has created technologies and best practices that can improve data center energy use significantly.    There have been some significant improvements made to data centers but much more needs to be done. Some of the new technologies and best practices applied to data centers will be described along with some thoughts on what the future holds for power and cooling of data centers and how some of these will affect the design of servers of the future. Data center technologies and best practices include the deployment of co-generation, higher server ambient temperatures, DC power, liquid cooling, and use of renewables will be described.

Bio

Dr. Roger R. Schmidt, IBM Fellow, National Academy of Engineering Member, IBM Academy of Technology Member and ASME Fellow, has over 30 years experience in engineering and engineering management in the thermal design of IBM’s large scale computers.  He is IBM’s Chief Engineer on Data Center Energy Efficiency. He has led development teams in cooling mainframes, client/servers, parallel processors and test equipment utilizing such cooling mediums as air, water, and refrigerants. He now leads IBM’s Advanced Thermal Energy Efficiency Lab which develops advanced electronic cooling technologies and provides customer support for power and cooling issues in data centers.  He has published more than 125 technical papers and has over 125 patents/patent pending in the area of electronic cooling. He is past Chair of the ASHRAE TC9.9 committee.